| 01Measurement & capture |
| Log-sweep frequency response | Yes | Yes | Yes | Log sweep with deconvolution; sweep lengths from 128k to 8M samples. |
| USB or analog measurement mic | Yes | Partial | Partial | Built-in mic, or a USB measurement mic like the UMIK-1 with its calibration file. Analog mics through an interface aren't a documented setup. |
| SPL meter as the input, with C-weighting compensation | Yes | No | No, planned | |
| Mic and soundcard calibration files | Yes | Partial | Partial | Mic calibration files (REW and miniDSP .cal). No soundcard calibration. |
| Loopback or acoustic timing reference | Yes | No | No, planned | Each sweep is timed on its own. |
| Offline measurement from recorded sweeps | Yes | No | No, planned | |
| Stepped-sine measurement, up to 96 points per octave | Yes | Partial | Partial | The Distortion Analyzer steps a sine through 22 third-octave points from 63 Hz to 8 kHz. |
| Clock-drift correction for separate input and output devices | Yes | No | No, planned | |
| ASIO driver support | Yes | Not applicable | Not applicable | A Windows driver standard. Audiophilio uses Apple's Core Audio. |
| 02Signal generator |
| Sine, with optional harmonics | Yes | Partial | Partial | Sine with octave, third-octave or fine frequency steps. No added harmonics. |
| Square wave | Yes | Yes | Yes | |
| Sawtooth | Yes | No | No, planned | |
| Dual, triple and multitone | Yes | No | No, planned | |
| Tone bursts and CEA-2010 bursts | Yes | No | No, planned | |
| Linear and log sweeps | Yes | No | No, planned | Sweeps run inside the measurement tools, not as a generator signal. |
| Random pink and white noise, with filtered variants | Yes | Partial | Partial | White, pink and brown noise. No speaker, sub or band-limited variants. |
| Periodic pink and white noise | Yes | No | No, planned | |
| Export signals to WAV | Yes | Yes | Yes | From both the Signal Generator and the Noise Generator. |
| 03Meters & real-time analysis |
| SPL meter with A, C and Z weighting | Yes | Yes | Yes | Also B and ITU-R 468 weighting, with Slow, Fast and Impulse response. |
| SPL calibration against a reference | Yes | Yes | Yes | Trim the live reading to match a reference meter or calibrator. |
| Integrating SPL: Leq and SEL | Yes | Partial | Partial | Shows minimum, average and peak. No true Leq or SEL integration. |
| SPL data logging | Yes | Yes | Yes | Record a session and export it as CSV. |
| Real-time analyzer, up to 1/48 octave | Yes | Partial | Partial | 31-band third-octave RTA. |
| Two-channel oscilloscope with a math channel | Yes | Partial | Partial | Single-channel scope with a zero-crossing trigger. |
| 04Frequency response & phase |
| Phase and group delay | Yes | Yes | Yes | |
| Minimum phase, excess phase and excess group delay | Yes | No | Yes, new in 2.0 | Shows which peaks and dips EQ can fix, and how far a sub lags the mains. |
| Minimum-phase response generation | Yes | No | Yes, new in 2.0 | Used for the phase overlay and for FIR export. |
| Phase wrap and unwrap | Yes | Partial | Partial | One fixed phase view (wrapped to ±180° in 2.0). No toggle. |
| 05Impulse & time domain |
| Impulse response | Yes | No | Yes, new in 2.0 | Computed from the same sweep as every other view. |
| Step response | Yes | No | Yes, new in 2.0 | |
| Energy-time curve (ETC) | Yes | Yes | Yes | A standalone tool and a Frequency Response view. |
| Adjustable impulse-response windows | Yes | No | No, planned | |
| Frequency-dependent windowing | Yes | No | No, planned | |
| Octave-filtered impulse response | Yes | No | No, planned | |
| Delay calculation and adjustment | Yes | Partial | Partial | Delay Finder measures speaker-to-mic delay and distance with a tone burst. |
| Sub and main alignment tool | Yes | No | No, planned | 2.0's excess group delay shows the timing offset, but there's no tool to align them. |
| 06Room acoustics |
| RT60 per ISO 3382: EDT, T20, T30, Topt | Yes | Partial | Yes, new in 2.0 | T20 today. 2.0 adds EDT, T30, Topt, curvature and fit quality, in octave bands from 125 Hz to 4 kHz (no third-octave bands). |
| Frequency-domain RT60 decay plot | Yes | No | No, planned | |
| Clarity and definition: C50, C80, D50, Ts | Yes | Partial | Yes, new in 2.0 | C50 and C80 today. 2.0 adds D50 and centre time, per octave band, as a table rather than a graph. |
| Speech Transmission Index (STI) | Yes, with REW Pro | Partial | Yes, new in 2.0 | Today, a rough estimate from C50. 2.0 computes STI from the impulse response per IEC 60268-16, included with Premium. |
| Room simulator, up to 8 subwoofers | Yes | Partial | Partial | Room Designer maps room modes as a heat map, plus first reflections and SBIR. It doesn't simulate a predicted response for multiple subs. |
| 07Distortion |
| Harmonic distortion: THD and individual harmonics | Yes | Partial | Partial | THD plus H2 to H8 at each stepped frequency. No harmonic phase, and no distortion from a sweep. |
| THD+N | Yes | Yes | Yes | Shown alongside THD. |
| Intermodulation distortion (IMD) | Yes | No | No, planned | |
| Multitone total distortion | Yes | No | No, planned | |
| 08Speakers & drivers |
| Electrical impedance | Yes | No | No, planned | The Impedance Analyzer plots an acoustic response that reflects impedance. True ohms need a sense-resistor rig. |
| EPDR (equivalent peak dissipation resistance) | Yes | No | No, planned | |
| Inductor and capacitor component model | Yes | No | No, planned | |
| Thiele-Small parameters (added mass, sealed volume) | Yes | Partial | Partial | Calculates Qms, Qes and Qts from values you read off an impedance curve. No added-mass or sealed-volume method. |
| 09Waterfalls & spectrograms |
| Fourier waterfall and spectral decay | Yes | Yes | Yes | In Frequency Response, plus a live Waterfall tool. |
| Burst-decay waterfall and spectrogram | Yes | No | No, planned | |
| Fourier spectrogram | Yes | Partial | Partial | A live spectrogram of the mic signal, not of a measured impulse response. |
| Wavelet spectrogram | Yes | No | No, planned | |
| 3D views | Yes | Yes | Yes | 3D waterfall. |
| 10Averaging & trace math |
| Measurement overlays | Yes | Yes | Yes | Overlay saved measurements and imported REW files. |
| RMS, vector and dB averaging | Yes | Partial | Partial, improved in 2.0 | dB average today. 2.0 switches to power (RMS) averaging and can build EQ from the average. No vector average. |
| Trace arithmetic: add, subtract, multiply, divide, merge | Yes | No | No, planned | |
| 11EQ & room correction |
| Automatic EQ to a target | Yes | Yes | Yes | Finds peaks and fits up to 32 parametric filters (peak and shelves) toward a target, with boosts capped. |
| Speaker-type and room-tilt target curves | Yes | Partial | Yes, new in 2.0 | Flat, Harman, House and imported targets today. 2.0 adds Subwoofer, Full Range and Room Tilt. No crossover modeling. |
| Tunable auto-EQ: match range, flatness, Q limits | Yes | No | No, planned | Uses fixed defaults. |
| Predicted response and live EQ'd waterfall | Yes | No | No, planned | |
| Room-mode analysis: frequency and decay time | Yes | No | Yes, new in 2.0 | Estimates each mode's frequency, level and T60 from the measured response. REW fits the impulse response instead. |
| Pole-zero plots | Yes | No | No, planned | |
| Modal filters, with Q matched to the mode's decay | Yes | No | Yes, new in 2.0 | Correct room modes adds cut filters whose Q matches each mode. |
| Configurable Q definitions | Yes | No | No, planned | |
| 12Import, export & hardware |
| Frequency response import and export (text) | Yes | Yes | Yes | REW-compatible text both ways, with phase where available. |
| Impulse response import (WAV, AIFF) | Yes | No | No, planned | |
| Export EQ filters as an impulse response (WAV) | Yes | No | Yes, new in 2.0 | Minimum-phase FIR at 44.1, 48, 88.2 or 96 kHz, for convolution engines. |
| Export a measurement's impulse response (WAV) | Yes | No | No, planned | |
| Filter files for named equalisers | Yes | Partial | Partial, improved in 2.0 | REW/Generic, miniDSP biquad and Equalizer APO today. 2.0 adds CamillaDSP and generic biquad coefficients. REW lists 30+ named devices. |
| Direct send to AV receivers and DSPs | Yes | No | No, planned | Planned where Apple platforms allow: MIDI and network control, and serial on Mac only. Until then, Audiophilio exports a file you load yourself. |
| Scripting API | Yes | No | No, planned | |
| Built-in help | Yes | Yes | Yes | Help for every tool, inside the app. |
| 13REW Pro upgradeSTI is also a Pro feature; it's listed under room acoustics. |
| Multi-input capture for mic arrays | Yes, with REW Pro | No | No, planned | One input at a time for now; planned for multichannel interfaces. Meanwhile, 2.0's guided multi-position capture builds a spatial average with a single mic. |
| +Beyond REWThings Audiophilio does that REW doesn't try to. |
| Runs on iPhone and iPad | No | Yes | Yes | REW runs on Windows, macOS and Linux. |
| Guided multi-position capture | Partial | No | Yes, new in 2.0 | Walks you through 3 to 9 seats, saves each sweep, averages them and reports seat-to-seat bass variation. In REW you take and average the measurements yourself. |
| LUFS loudness meter | No | Yes | Yes | |
| Polarity checker | Partial | Yes | Yes | In REW you read polarity from the impulse response. |
| Wow and flutter | No | Yes | Yes | |
| Turntable setup suite | No | Yes | Yes | Tonearm alignment and speed stability. |
| Room Designer with LiDAR room scanning | No | Yes | Yes | Scan a room, place speakers and treatment, and see standing waves and reflections before you buy anything. |
| System Builder with diagnosis | No | Yes | Yes | Finds problems in your signal chain and ranks them, with plain-English fixes. |
| Ear Trainer | No | Yes | Yes | Learn to hear all 31 third-octave bands. |
| Acoustic calculators | No | Yes | Yes | Eleven, including room modes, first reflections, SBIR, Schroeder frequency, crossovers and cartridge resonance. |
| iCloud sync across your devices | No | Yes | Yes | |